8
This unit is protected by security device.
Should the unit not work properly, due to a defective power component,
the security would instantly stop the charge.
The power pack requires a check up at a technical Elinchrom service.
Overvoltage security
Relation of power range between the outlets
Guide aperture is based on the " Digital S or Digital SE " lamphead and the 50° reector,
distance 1 m/3.3 ft and lm ISO 100/21 DIN.
Digital 1200 RX Digital 2400 RX
Scale Ws f-stop Scale Ws f-stop Power
7.5 1200 (128) 8.5 2400 (180) 1/1
6.5 600 (90) 7.5 1200 (128) 1/2
5.5 300 (64) 6.5 600 (90) 1/4
4.5 150 (45) 5.5 300 (64) 1/8
3.5 75 (32) 4.5 150 (45) 1/16
2.5 37.5 (22) 3.5 75 (32) 1/32
Main Supply
While the MAINS SWITCH (3) is switched OFF (not illuminated), rmly push in the plug of the
original ELINCHROM mains cord (1).
Standard type 5 x 20 mm, 16 AT (tempered). Before exchanging a blown fuse, switch off the unit
and remove mains cable. Depress and turn the fuse holder anti-clockwise 1/8th and remove it.
If the new fuse blows immediately upon reconnection return the pack to an ELINCHROM service
centre for a check-up.
(N.B. Check correct value of the fuse: 16 AT).
Fuse
Fuses for ashheads
Use only FAST BLOW FUSES, type 5 x 20 mm corresponding to the label on each ashhead.
Different modelling lamps require corresponding fuses. Slow blow fuses will not protect the
modelling lamp. The fast blow fuse will protect the triac of the modelling lamp circuit, the
lamp and therefore the ash tube.
Modelling Lamp-
switch
Fuse
Fuse
W 110V 240V
200 2 AF 2 AF
250 5 AF 2.5 AF
300 5 AF 2.5 AF
650 10 AF 5 AF
Only use recommended fuse